How to choose the power of heater

The required power of heater depends on size of room, its insulation, outside temperature. The following table gives recommendations what power depending on the size and height of the room with standard insulation best suit you premises. If the ceiling higher or insulation is poorer, it is recommended to choose bigger power heater.
 
 
Mild climate (temperature seldom
drops below - 200C) 60-70 W/m2
Normal/cold climate (temperature
often drops below  - 200C) 70-85 W/m2
Heater power, W Room size, m2 (ceiling height up to 2,4 m) Room size, m2 (ceiling height up to 2,4 m)
400 3 - 7 m2 3 - 6 m2
600 8 - 10 m2 7 - 9 m2
800 11 - 14 m2 9 - 11 m2
1000 14 - 16 m2 12 - 14 m2
1200 17 - 20 m2 14 - 17 m2
1400 21 - 25 m2 17 - 21 m2
2000 26 - 34 m2 22 - 29 m2
2500 35 - 40 m2 30 - 35 m2

Also you can calculate your required power by pressing here...
 